beautypg.com

Trane INTELLIPAK ™ ™ ™ ™ ™ Commercial Single-Zone Rooftop Air Conditioners with CV or VAV Control User Manual

Page 5

background image

5

Sample Model No.: S X H G - D 1 1 4 0 A H 7 C G 8 D 1 0 0 1 AT,etc
Digit No.: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21+

Digit 1 - Unit Type

Digit 12 - Exhaust Air Fan Drive

Digit 18 - Accessory Panel

S = Self-Contained

0 = None

0 = None

5 = 500 RPM

A = BAYSENS008*

Digit 2 - Unit Function(s)

6 = 600 RPM

B = BAYSENS010*

E = DX Cooling, Electric Heat

7 = 700 RPM

C = BAYSENS013*

F = DX Cooling, Natural G as Heat

8 = 800 RPM

D = BAYSENS014*

L = DX Cooling, Hot Water Heat

E = BAYSENS019*

S = DX Cooling, Steam Heat

Digit 13 - Filter

F = BAYSENS020*

X = DX Cooling, Extended Casings

A = Throwaway

G = BAYSENS021*

C = High-Efficiency Throwaway

Digit 3 - Unit Airflow

D = Bag with Prefilter

Digit 19 - Ambient Control

H = Single-Zone

E = Cartridge with Prefilter

0 = Standard

F = Throwaway Filter Rack Less Filter

Digit 4 - Development Sequence

Media

Digit 20 - Agency Approval

G = Seventh G = Bag Filter Rack Less Filter Media 0 = None (UL Gas Heater See Note 1)

1 = UL

Digits 5, 6, 7 - Nominal Capacity

Digit 14 - Supply Air Fan HP

2 = CSA

C90 = 90 Tons

C = 30 HP (2-15 HP)

Note: Includes UL classified gas

D11 = 105 Tons

D = 40 HP (2-20 HP)

heating section only w hen second

D12 = 115 Tons

E = 50 HP (2-25 HP)

digit of Model No. is a "F".

D13 = 130 Tons

F = 60 HP (2-30 HP)
G = 80 HP (2-40 HP)

Digits 21 - 36 - Miscellaneous

Digit 8 Pow er Supply

21 A = Unit Disconnect Switch

4 = 460/60/3 XL Digit 15 - Supply Air Fan Drive 22 B = Hot G as Bypass
5 = 575/60/3 XL

A = 1000 RPM

23 C = Economizer Control

E = 200/60/3 XL

B = 1100 RPM

with Comparative Enthalpy

F = 230/60/3 XL

C = 1200 RPM

23 Z = Economizer Control

D = 1300 RPM

with Reference Enthalpy

Digit 9 - Heating Capacity

E = 1400 RPM

23 W = Economizer Control w/Dry Bulb

0 = No Heat

F = 1500 RPM

23 0 = None W/O Economizer

H = High Heat - 2 Stage

G = 1600 RPM

24 E = Low-Leak Fresh Air Dampers

J = Limited Modulating High Heat

25 F = High Duct Temperature Thermostat

P = Full Modulating High Heat

26 G = High Capacity Evaporator

Note: When the second digit calls

Digit 16 - Fresh Air

Coil (90 - 105 O nly)

for "E" (electric heat), the follow ing

D = 0-100% Economizer (Std.)

27 K = G eneric BAS Module

values apply in the ninth digit:

28 L = High Efficiency Motors

W=190 kw

Digit 17 - System Control

(Supply and Exhaust)

Note: When the second digit calls for

1 = Constand Volume Control

29 M = Remote Human Interface

"L" or "S", one of the following valve

2 = VAV Supply Air Temperature

30 N = Ventilation O verride Module

size values must be in Digit 9:

Control without Inlet G uide Vanes

31 R = Extended Grease Lines

High Heat Coil: 3 = 1.0", 4 = 1.25",

3 = VAV - Supply Air Temperature

32 T = Access Doors

5 = 1.50", 6 = 2.0", 7 = 2.5"

Control with Inlet Guide Vanes

33 V = Inter-processor Communication

Low Heat Coil: C = 1.0", D = 1.25",

4 = Space Pressure Control with

Bridge

E = 1.50", F = 2.0", G = 2.5"

Exhaust VFD w/o Bypass

34 0 = No communication module

5 = Space Pressure Control with

34 Y = Trane Communication Interface Module

Digit 10 - Design Sequence

Exhaust and Bypass

34 7 = LonTalk® Communication Interface Module

W = Disconnect Redesign

6 = VAV Supply Air Temperature Control

35 0 = None

Note: Sequence may be any letter

with VFD without Bypass

36 6 = Factory-Powered 15A G FI

A thru Z, or any digit 1 thru 9.

7 = VAV Supply Air Temperature Control

Convenience O utlet

with VFD and Bypass
8 = Supply and Exhaust Fan with

Digit 11 - Exhaust O ption

VFD and without Bypass

O = None

9 = Supply and Exhaust Fan with

7 = 100%, 15 HP w/ Statitrac

VFD and Bypass

8 = 100%, 20 HP w/ Statitrac
9 = 100%, 25 HP w/ Statitrac
F = 50%, 15 HP
H = 100%, 30 HP w/ Statitrac
J = 100%, 40 HP w/ Statitrac
K = 100%, 15 HP w/o Statitrac (CV O nly)
L = 100%, 20 HP w/o Statitrac (CV O nly)
M = 100%, 25 HP w/o Statitrac (CV O nly)
N = 100%, 30 HP w/o Statitrac (CV O nly)
P = 100%, 40 HP w/o Statitrac (CV O nly)

Echelon, LON, LONWORKS, LonBuilder, NodeBuilder, LonManager,
LonTalk, LonUsers, Neuron, 3120, 3150, the Echelon logo, and the
LonUsers logo are trademarks of Echelon Corporation registered in the
United States and other countries. LonLink, LonResponse, LonSupport,
LonMaker, and LonPoint are trademarks of Echelon Corporation.