General Information

Model Number Description

All products are identified by a multiple character model
number listed on the unit nameplate. An explanation of the
alphanumeric identification code is provided below. Its use
can define the unit's specific components, type of applica-
tion, i.e. CV or VAV, for a particular unit.

When ordering replacement parts or requesting service, be
sure to refer to the specific model number, serial number,
and DL number (if applicable) stamped on the unit name-
plate.

Sam ple Model No.: S X H F - C20 4 0 A 1 0 A 1 5 B 1 D 0 1 A,R,L,etc.
Digit No.: 1 2 3 4 5,6,7 8 9 10 11 12 13 14 15 16 17 18 19 20 21+

Digit 1 - Unit Type

Digit 10 - Design Sequence

Digit 17 - System Control

S = Self-Contained

3 = Dis connect Redes ign

1 = CV Control (Zone Control)

Note: Sequence may be any letter

2 = VAV-(S/A Temp Control

Digit 2 - Unit Function

A thru Z, or an y digit 1 thru 9.

without Inlet Guide Vanes)

A = DX Cooling, No Heat

3 = VAV-(S/A Temp Control

E = DX Cooling, Electric Heat

Digit 11 - Exhaust Option

with Inlet Guide Vanes)

F = DX Cooling, Natural Gas Heat

0 = None

4 = Space Press ure Control with Exhaus t VFD

L = DX Cooling, Hot Water Heat

1 = Barometric

without By pass

S = DX Cooling, Steam Heat

2 = 100% - 1.5 HP*

5 = Space Press ure Control with Exhaus t VFD

X = DX Cooling, Extended Cas ings

3 = 100% - 3 HP*

and Bypas s

# = DX Cooling, Propane Gas Heat

4 = 100% - 5 HP*

6 = VAV Supply Air Temperature Control

5 = 100% - 7.5 HP*

with VFD w/o Bypas s

Digit 3 - Unit Airflow

6 = 100% - 10 HP*

7 = VAV Supply Air Temperature Control

H = Single-Zone

7 = 100% - 15 HP*

with VFD and Bypass

8 = 100% - 20 HP*

8 = Supply and Exhaus t Fan with VFD

Digit 4 - Development Sequence A = 50% - 1.5 HP

without Bypass

F

= Six th B = 50% - 3 HP 9 = Supply and Exhaus t Fan with VFD

C = 50% - 5 HP

and By pas s

Digits 5, 6, 7 - Nominal Capacity

D = 50% - 7.5 HP

C20 = 20 Tons C55 = 55 Tons

E = 100% - 1.5 HP**

Digit 18 - Accessory Panel

C25 = 25 Tons C60 = 60 Tons

F = 100% - 3 HP**

0 = None

C30 = 30 Tons C70 = 70 Tons G = 100% - 5 HP** A = BAYSENS008*
C40 = 40 Tons C75 = 75 Tons

H = 100% - 7.5 HP**

B = BAYSENS010*

C50 = 50 Tons

J = 100% - 10 HP**

C = BAYSENS013*

K = 100% - 15 HP**

D = BAYSENS014*

Digit 8 - Power Supply

L = 100% - 20 HP**

E = BAYSENS019*

4 = 460/60/3 XL

# = 50% w/ Statitrac

F = BAYSENS020*

5 = 575/60/3 XL

* w/Statitrac

G = BAYSENS021*

E = 200/60/3 XL

** w/o Statitrac (CV only )

F = 230/60/3 XL

Digit 19 - Ambient Control

Note: SEHF units (unit with

Digit 12 - Exhaust Fan Drive

0 = Standard

electric heat) utiliz ing 208V or

0 = None 8 = 800 PRM

1 = 0 Degree Fahrenheit

230V require dual power source.

4 = 400 RPM 9 = 900 RPM
5 = 500 RPM A = 1000 RPM

Digit 20 - Agency Approval

Digit 9 - Heating Capacity

6 = 600 RPM B = 1100 RPM

0 = None (UL Gas Heater, s ee note)

7 = 700 RPM

1 = UL

Note: When the second digit

2 = CSA

calls for "F" (Gas Heat), the

Digit 13 - Filter Type

Note: Includes UL clsssified gas heating

follow ing values apply:

A = Throwaway

section only when second digit of

Additionally, please note G and

B = Cleanable Wire Mes h

Model No. is a "F".

M available ONLY on 50 Ton

C = High-Efficienc y Throwaway

models and above.

D = Bag with Prefilters

Digits 21 - 38 - Miscellaneous

H = High Heat - 2 Stage

E = Cartridge with Prefilters

21 A = Unit Disc onnec t Switc h

L = Low Heat - 2 Stage

F = No Filters (T/A Rack Only)

22 B = Hot Gas Bypas s

0 = No Heat

G = No Filters (Bag/Cart. Rack O nly)

23 C = Economizer Control w/Comparative

J = Limited Modulating High Heat

Enthalpy

G = Limited Modulating Low Heat

Digit 14 - Supply Fan Horsepower

23 Z = Economizer Control w/Reference

P = Full Modulating High Heat

1 = 3.0 HP 6 = 20.0 HP

Enthalpy

M = Full Modulating Low Heat

2 = 5.0 HP 7 = 25.0 HP

23 W = Economiz er Control w/Dry Bulb

Note: When the second digit

3 = 7.5 HP 8 = 30.0 HP

23 O = None W/O Economiz er

calls for "E" (electric heat), the

4 = 10.0 HP 9 = 40.0 HP

1

24 E = Low Leak Fres h Air Dampers

follow ing values apply:

5 = 15.0 HP

25 F = High Duct Temperature Thermos tat

D = 30 KW R = 130 KW

26 G = High Capacity Ev aporator Coil

H = 50 KW U = 150 KW

Digit 15 - Supply Fan Drive

27 H = Copper Fins (Cond. only)

L = 70 KW V = 170 KW

5 = 500 RPM B = 1100 RPM

28 K = Generic B.A.S. Module

N = 90 KW W = 190 KW

6 = 600 RPM C = 1200 RPM

29 L = High-Efficiency Motors (Supply & Exhaust)

Q = 110 KW

7 = 700 RPM D = 1300 RPM

30 M = Remote Human Interfac e

Note: When the second digit calls

8 = 800 RPM E = 1400 RPM

31 N = Ventilation Override Module

"L" (Hot Water) or "S" (Steam)

9 = 900 RPM F = 1500 RPM

32 R = Extended Grease Lines

Heat, one of the following valve

A = 1000 RPM G = 1600 RPM

33 T = Acc es s Doors

size values must be in Digit 9:

34 V = Interproc ess or Communic ations Bridge

High Heat Coil: 1 = 50", 2 = .75",

Digit 16 - Fresh Air Section

35 0 = No c ommunication module

3 = 1", 4 = 1.25", 5 = 1.5", 6 = 2".

A = No Fresh Air

35 Y = Trane Communic ation Interfac e Module

Low Heat Coil: A = .50", B = .75",

B = 0-25% Manual

35 7 = LonTalk® Communication Interface Module

C = 1", D = 1.25", E = 1.5", F = 2".

D = 0-100% Ec onomizer

36 8 = Spring Is olators
37 6 = Factory-Powered 15A G FI Conv enienc e
O utlet
38 0 = None

1. Available as standard 460 volt only for 70 and 75 ton models.