Notes

• Automatic adjustment may not be performed properly for signals other than those computers’

signals with which the projector is compatible.

• The horizontal position, vertical position, sampling phase and sampling frequency can also be

adjusted from the menu screen

47

.

* Sampling frequency

Analog RGB signals input from the computer are converted into digital signals inside the
projector. The sampling frequency is the number of times per second the analog signals are
converted into digital signals. In order to capture (sample) each individual dot of the
computer’s signals, the sampling frequency must be adjusted to match the computer’s dot
clock frequency. If this adjustment is off, details of the image details may be blurred, a striped
pattern may appear if images with many vertical lines are displayed, or the image’s width may
change. For computer signals with which are projector-compatible, the sampling frequency is
adjusted automatically even when the AUTO SET button is not pressed.

* Sampling phase

The sampling phase is the timing at which the computer’s analog RGB signals are sampled. If
the sampling phase is off, the individual dots cannot be sampled at the proper timing, resulting
in blurred or flickering images.

Adjusting the picture automatically

1

2

MENU

ON /

INPUT

ENTER

CT-90106

KEYSTONE

AUTO SET

EXIT /

P.MODE

P I P

FREEZE

MUTE

CALL

RESIZE

VOL / ADJ

STANDBY

K

EY

ST

O

N

E

AU

TO

SE

T

EXIT

ON / STANDBY

VOL / ADJ

ENT

ER

M

EN

U

IN

P

U

T

FAN

TEMP

LAMP

ON

2

2

You can adjust the optimum horizontal position, vertical position, sampling phase and
sampling frequency for projecting analog RGB signals at the touch of a button.

AUTO SET

AUTO SET

Input full screen video signals from the input
source (computer) and project the image.

Adjustments may not be performed properly for images that are
not displayed on the entire screen or for extremely dark
images.

Press AUTO SET.

The horizontal position, vertical position, sampling phase and
sampling frequency are adjusted automatically.

The icon