Trango Broadband Access5830 User Manual
Page 60

Management
Trango Broadband Wireless — Access5830 User Manual Rev. F
page 56
Command Description
AP/S
U Remarks
reset [
reset radio to factory default settings
Parameters are in groups.
The following parameters will be
reset for the AP:
0 - BASE ID = 1, AP ID = 1
Subnet Mask =
255.255.255.0
Gateway = radio IP
Password = trango
1 - Channel Tables
Active Channel = 1 h
2 - TX Power = Max
RF Threshold = -90 dBm
Target RSSI = -60 dBm
Service Radius (ISM/UNII)
= (10/4) mi
MIR Threshold = off
3 - SNMP Community String
(Read/Write) =
(public/private)
SU:
0 - BASE ID = 1, AP ID = 1
SU ID = 1
Subnet Mask =
255.255.255.0
Gateway = radio IP
Password = trango
1 - Channel Tables
Scan Table = 1 h 7 h
Active Channel = 1 h
2 - TX Power = Max
RF Threshold = -90 dBm
Both Examples:
reset all – resets parameters 0-3.
reset 0 – resets Base ID, AP ID,
subnet, gateway, and password.
reset 1 - resets channel tables
Note: parameter #3 does not
apply to SU
restart
same as “reboot”
rfrxth [
Both
default = -90 dBm for both bands
rfrxthreshold …
same as “rfrxth” Both
rssi
display current RX RSSI from
associated radio
Both
rssi r +
display RX RSSI continuously
Both
save
same as “updateflash” Both
Examples:
save ss (save system settings)
save sudb (save SUDB changes)
save mainimage (update flash
memory with new firmware)
set apid
set AP ID,
Both
set baseid
set base station id,
1..127
Both
set defaultopmode ap
set default Opmode to be AP,
= 0..10
AP
default Opmode is AP, 0 = 30 s
set defaultopmode su
set default Opmode to be SU,
= 0..10
SU
default Opmode is SU, 0 = 30 s
set gateway [
set or display gateway’s IP
AP
If IP is 0.0.0.0, or