beautypg.com

Toshiba Tosvert RS485 User Manual

Page 54

background image

E6581315

53

„

Inverter operating status 2 (FD42, FE42)

Inverter status 2 (current status): Communication Number FD42
Inverter status 2 (status immediately before the occurrence of a trip): Communication Number FE42

Bit

Function

0

1

Remarks

0

Control mode switching

Speed control

(Simple posi-

tioning)

Torque control

1

Electric Power Counting

(FE76,FE77) status

Counting

Resetting

2

(Reserved)

-

-

3

(Reserved)

-

-

4

Preliminary excitation

Normal

Operation

5

(Reserved)

-

-

6

(Reserved)

-

-

7

Maximum deceleration forced

stop

Normal

Operation

8

Acceleration/deceleration

pattern selection1

9

Acceleration/deceleration

pattern selection2

00:Acceleration/deceleration 1

01:Acceleration/deceleration 2

10:Acceleration/deceleration 3

11:Acceleration/deceleration 4

Acceleration/ decelera-

tion 1 - 4 can be specified

by combination of two

bits

10

V/Fswitching 1

11

V/Fswitching 2

00: V/F 1
01: V/F 2
10: V/F 3
11: V/F 4

Select V/F 1 - 4 by com-
bination of two bits

12

Torque limit switching 1

13

Torque limit switching 2

00: Torque limit 1
01: Torque limit 2
10: Torque limit 3
11: Torque limit 4

Select torque limit 1 - 4
by combination of two
bits

14

Speed gain 1/2

Gain 1

Gain 2

Gain 1: , 
Gain 2: , 

15

(Reserved)

-

-

„

Inverter operating status 3 (FD49, FE49)

Inverter status 3 (current status): Communication Number FD49
Inverter status 3 (current status): Communication Number FE49

Bit

Function

0

1

Remarks

0 to 11 (Reserved)

-

-

12

Acceleration/deceleration

completion (RCH)

Not achieved

Achieved

Related parameters

f102

13

Specified speed reach (RCHF)

Not achieved

Achieved

Related parameters

f101

, f102

14 to 15 (Reserved)

-

-

This manual is related to the following products: