beautypg.com

Toshiba Tosvert RS485 User Manual

Page 17

background image

E6581315

16

2) Error Processing (Binary mode)

In case an error occurs, communication error command (4EH(N) or 6EH(n)) and the error type num-
ber is returned to the computer in addition to the checksum.

Omissible


(3.5bytes

Blank)

“/”

(2FH)

INV-NO

1 byte

Norn

(4EH)(6EH)

DATA

2 bytes

SUM

1 byte

(3.5bytes

Blank)


Checksum area

Not omissible

“N” or “n” (1 byte) : Communication error command. Also for check during an inverter trip (includes standing

by for retrying and trip holding). “4EH (N)” when normal, “6EH (n)” during an inverter trip.

DATA (2 bytes)

: Error code (0004)
0004

: Checksum error (The checksum does not match)

No return : Command error, format error (specified number of bytes is not received in 1sec,

or parity error, overrun error or framing error), inverter number mismatch, and
inverter number other than 00H in broadcast communication.

„

Examples

Computer → Inverter : 2F 58 02 05 C4 00 17 70 D8

Inverter → Computer : 2F 4E 00 04 81 ... Checksum error

This manual is related to the following products: