CLOCK DATA RETURN
This is the return command in response to the command “CLOCK DATA PRESET [27].”
It returns the currently specified date and time value.
Command A7
Machine ID
0
Data
1 2 bytes
Description Remarks
Data 1
Tens digit of year
Data 2
Ones digit of year
Data 3
Tens digit of month
Data 4
Ones digit of month
Data 5
Tens digit of day
Data 6
Ones digit of day
Data
7 Tens digit of the
hours
Data
8 Ones digit of the
hours
Data
9 Tens digit of the
minutes
Data
10 Ones digit of the
minutes
Data
11 Tens digit of the
seconds
Data
12 Tens digit of the
seconds
Request/Preset CLOCK DATA PRESET [27]
SYNC REC LEVEL RETURN
This is the return command in response to the command "SYNC REC LEVEL PRESET [28]."
It returns the currently specified Sync Rec level.
Command A8
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0 0
Preset
–24dB
0 1
Preset
–30dB
0 2
Preset
–36dB
0 3
Preset
–42dB
0 4
Preset
–48dB
0 5
Preset
–54dB
0 6
Preset
–60dB
0 7
Preset
–66dB
0 8
Preset
–72dB
Request/Preset SYNC REC LEVEL PRESET [28]