Tascam SS-R1 User Manual
Page 12
TASCAM SS-R1/SS-CDR1 RS-232C Protocol Specification
11
TEAC
Corporation
PITCH CONTROL DATA PRESET
Specifies the playback pitch of the controlled device in % units.
The adjustable range is ±16.0%.
This can be set independently of the step that is specified by the SS-R1/SS-CDR1's PITCH STEP?
setting.
A return command is returned only if Sense [FF] is specified..
If Sense [FF] is specified, the data is two bytes.
The pitch control mode setting is made by the command "PITCH CONTROL SELECT [35]."
Command 25
Machine ID
0
Data
4 bytes or 2 bytes
Data
1
Data
2
Data
3
Data
4
Description Remarks
0
1
Positive
value
Negative value
N2 N3 N1
Preset %
N1:Tens digit, N2: Ones digit, N3:First decimal
place
Example) 2311:-12.3%
F
F
…
Sense
Requests that the currently preset pitch be
returned.
・
If data other than the above or data outside the specified operating range is received, the
SS-R1/SS-CDR1 will transmit ILLEGAL [F2].
Return
PITCH DATA RETURN [A5]
AUTO TRACK TIME PRESET
Specifies the Auto Track Time setting of the controlled device.
The range that can be specified is 1 to 10 minutes.
A return command is returned only if Sense [FF] is specified.
The Auto Track Mode setting is made by the command "AUTO TRACK SELECT [31]."
Command 26
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
N1 N2
Minutes N1: Tens digit of minutes, N2: Ones digit of minutes
F
F
Sense
Requests that the currently preset time be returned.
・
If data outside the specified range is received, the controlled device will return ILLEGAL[F2].
Return