Tascam SS-R1 User Manual
Page 13

TASCAM SS-R1/SS-CDR1 RS-232C Protocol Specification
12
TEAC
Corporation
CLOCK DATA PRESET
Sets the date and time of the controlled device.
Command 27
Machine ID
0
Data
10 bytes or 2 bytes
Description Remarks
Data 1
Tens digit of year
Data 2
Ones digit of year
Data 3
Tens digit of month
Data 4
Ones digit of month
Data 5
Tens digit of day
Data 6
Ones digit of day
Data
7 Tens digit of the
hours
Data
8 Ones digit of the
hours
Data
9 Tens digit of the
minutes
Data
10 Ones digit of the
minutes
e.g., “0802231234” means February 23
rd
of year
2008 at 34 minutes past twelve o’clock.
If both Data 1 and Data 2 are “F,” “Sense” is
specified and the SS-R1/SS-CDR1 requests that the
currently programmed Clock Data be returned.
e.g., FF
・
If a date or time outside the possible range is set, the SS-R1/SS-CDR1 will return ILLEGAL
[F2].
Return
CLOCK DATA PRESET RETURN [A7]
SYNC REC LEVEL PRESET
Sets the Sync Rec Level of the controlled device.
A return command is returned only if Sense [FF] is specified.
The SYNC REC MODE setting is made by the command "SYNC REC SELECT [38]."
Command 28
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0 0
Preset
–24dB
0 1
Preset
–30dB
0 2
Preset
–36dB
0 3
Preset
–42dB
0 4
Preset
–48dB
0 5
Preset
–54dB
0 6
Preset
–60dB
0 7
Preset
–66dB
0 8
Preset
–72dB
F
F
Sense
Requests that the currently preset level be returned.
・
If data outside the above range is received, the SS-R1/SS-CDR1 will return ILLEGAL [F2].
Return
SYNC REC LEVEL RETURN [A8]