Troubleshooting and Maintaining an SDS

Quatech SDS User’s Manual

Page 80

940-0183-154

October 2006

Troubleshooting and Maintaining an SDS

Troubleshooting an SDS

This section lists some common problems and their causes. If the

information below does not provide a solution, contact Quatech

technical support.

Problem

Cause

Solution

The SDS does not
turn on and no

LEDs light up.

¾

The SDS or the
power source is

damaged, or the SDS
does not have power.

1.

Make sure that the power source is properly
connected to the SDS’ power jack.

Caution! Only use the Quatech +5 V power source.

2.

Make sure the power adapter is connected to a

functioning electrical outlet.

3.

Contact Quatech tech support.

The serial device

will not respond
even though the

SDS is functioning.

¾

The serial device is

not powered up; the
serial cable is

wrong/damaged, or

the serial port
settings are wrong.

1.

Make sure the serial device is powered up.

2.

Make sure the serial cable is properly

connected to the serial device and to the SDS.

3.

Verify the cable pinouts.

4.

Try a different serial cable.

5.

Try a different port on the SDS.

6.

Review your serial device literature. Make sure

the settings it specifies match those the SDS is

using (check the SDS serial port settings using
the Web interface).

7.

Try plugging the serial device directly into a
PC.

The search utility
does not find the

SDS.














Could be due to a
variety of causes:

¾

Check power



¾

Check status






Verify that the blue Power LED is lit.

If the Power LED is not lit,
1. Check the power connection.
2. If power is connected properly, contact Quatech

tech support.

Verify that the green Status LED is lit.

If the Status LED is not lit,
1. Check the firmware version.

a. If the SDS firmware has been upgraded

from the factory default, reset the SDS to

the factory default. See page 9.

b. If the procedure to return to factory default

fails, contact Quatech tech support.

2. Cycle power on the box and wait approximately

30 seconds. If the Status LED still does not

light, contact Quatech tech support.

Note: Any unauthorized repairs
or modifications will void the
SDS' warranty.