36

Select Code ID(s)

This command designates the bar code symbologies or magnetic stripe tracks

that will be accepted as valid.

SELECTION CODE: JC

UPC-A

a

UPC-E

b

EAN-8

c

EAN-13

d

Code 39

e

Interleaved 2 of 5

f

Industrial 2 of 5

g

Code 128

h

MSI/Plessey

i

Codabar

j

MSR Track 1

k

MSR Track 2

l

MSR Track 3

m

Telepen

n

EXAMPLE:

To designate UPC-A, Code 39, Codabar, and MSR Track 1 as the only valid

sources of data, enter:

... JCaejk ...

Set Length

Use this command to indicate a minimum and maximum number of

characters allowed for valid data. The first two digits set the minimum

length, and the second two digits set the maximum length. (This command is

optional.)

SELECTION CODE: JD

Two Digits for Minimum Length

Two Digits for Maximum Length

EXAMPLE:

To set the minimum number of characters at six, and the maximum at twelve,

enter:

... JD0612 ...