Omnitron Systems Technology iConverter Network Management Module User Manual
Page 2
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • [email protected] • 140 Technology Dr. • Irvine, CA 92618
Trademarks are owned by their respective companies. iConverter and NetOutlook are registered trademarks of Omnitron Systems Technology, Inc.
Specifications subject to change without notice. ©2008 Omnitron Systems Technology, Inc. All rights reserved.
091-18000-001H
12/08
Alarms / Traps
•
Warm Start
•
Link Up/Down
•
Chassis Insertion/Removal
•
Authentication Failure
•
DIP-Switch Configuration Change
•
Software Configuration Change
•
Temperature Out-of-Range
•
Power Supply Out-of-Range
•
Power Supply Insertion/Removal
•
Chassis Reset
•
Module Reset
•
Module Insertion/Removal
•
Port Link State Change
•
Redundancy Primary Up/Down
•
Redundancy Secondary Up/Down
•
FTP Session Open/Close
•
Telnet Session Open/Close
•
Dying Gasp (Power Loss Trap)
Active Controls
•
Link Propagate/Link Segment
•
Remote Fault Detection
•
Module Name
•
Chassis Name and Number
•
IP Address
•
802.3ah OAM Enable
•
Secure IP-less OAM Enable
•
Subnet Mask
•
Gateway
•
Management Port Disable
•
Alarm Threshold Setting
•
Download Software via FTP
•
Reset Chassis
•
Telnet
•
Trap IPs
•
FTP Enable
•
Password Selection
•
Soft Switch Reload
IP-less management requires an NMM in the core chassis, and
a media converter with integrated management installed at each
remote end of the IP-less managed link. An
iConverter
10/100M2
plug-in module is installed in the 19-Module chassis, and
connected via the fiber link to a standalone 10/100M2 Network
Interface Device (NID). This configuration enables the 19-Module
master chassis to establish an IP-less management channel
between the 10/100M2 link partners. The IP address
resides only at the network core, and does not exist on the
customer network.
Model
Description
8000-0
iConverter NMM Module w/ Dying Gasp Support
8080-3
NMM Cascade Cable (3 ft.)
8081-3
NMM Serial Cable (DB-9, 3 ft.)
Model Type
NMM
Protocols
IP, UDP, SNMPv1, SNMPv2c, SNMPv3,
Telnet, TCP, FTP, ARP, ICMP, 802.3ah
Connectors
RJ-45, DB-9
Controls
UTP cross-over, Frontplane / Backplane
LED Displays
Power, Power Supply (3), UTP link,
Master, Slave, Mgt. Poll
Supported MIBs
RFC1155, RFC1156, RFC1157,
RFC1212, RFC1213, OST MIB
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A, NEBS 3
Power Requirement
0.32A @ 3.3VDC (typical)
Temperature
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
786,000
Chassis Information
•
Part Number
•
Serial Number
•
Revision
•
Description
Chassis Status
•
Power Status
•
Power Output Voltage
•
Chassis Temperature
Module Status
•
Module Power
•
Link Status
•
Active Port
•
Diagnostic Status
•
Management
Module Information
•
Module Type
•
Slot Occupied
•
Part Number
•
Serial Number
•
Configuration
•
Revision
•
Ports on Module
•
User-defined Identifier