Ordering Information

CPU Bus Units

CPU Bus Units

Controller Link Units

Controller Link Units, New Models

Controller Link Units, Old Models

New models are fully compatible with old models and provide enhanced functionality, such as an increase in the number of send words from

1,000 to 4,000 words. Select a new model when ordering.

Note: Use the following special cable for shielded, twisted-pair cable.

ESVC0.5 x 2C-13262 (Bando Electric Wire: Japanese Company)

ESNC0.5 x 2C-99-087B (Nihon Electric Wire & Cable Corporation: Japanese Company)

ESPC 1P x 0.5 mm

2

(Nagaoka Electric Wire Co., Ltd: Japanese Company)

Li2Y-FCY2 x 0.56qmm (Kromberg & Schubert, Komtec Department: German Company)

1 x 2 x AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)

#9207 (Belden: US Company)

Repeater Units

Note: 1. Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks. 62-node configurations, and con-

verting part of the network to optical cable.

2. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable

with connector.

3. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).

Relay Terminal Block

Note: Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in

advance on the Unit in a Wired Controller Link network. Relay Blocks cannot be used on Controller Link Support Boards.

Unit

classifi-

cation

Product

name

Specifications

No. of unit

numbers

allocated

Current con-

sumption (A)

Model

Standards

Communica-

tions cable

Communi-

cations

type

Duplex

support

Max. Units
mountable

per CPU

Unit

5 V

24 V

CJ1
CPU
Bus
Unit

Control-
ler Link
Unit

Wired shielded
twisted-pair cable
(See note 2.)

Data links
and mes-
sage service

No

8

1

0.35

---

CJ1W-CLK23

UC1, N, L,
CE

Unit

classifi-

cation

Product

name

Specifications

No. of unit

numbers

allocated

Current con-

sumption (A)

Model

Standards

Communica-

tions cable

Communi-

cations

type

Duplex

support

Max. Units
mountable

per CPU

Unit

5 V

24 V

CJ1
CPU
Bus
Unit

Controller
Link Unit

Wired shielded
twisted-pair cable
(See note 2.)

Data links
and mes-
sage service

No

8

1

0.35

---

CJ1W-CLK21-V1 UC1,

N,

L,

CE

Unit classification

Specifications

Model

Standards

Controller Link
Repeater Unit

Wire-to-wire Model

CS1W-RPT01

UC1, CE

Wire-to-Optical (H-PCF) Model (See note 2.)

CS1W-RPT02

Wire-to-Optical (GI) Model (See note 3.)

CS1W-RPT03

Unit classification

Specifications

Model

Standards

Relay Terminal Block
for Wired Controller
Link Unit

Use for Wired Controller Link Units (set of 5).

CS1W-TB101

---

CS1W-RPT01

PWR

T/R1

T/R2

SL1

TER SW

TER SW

ON

SL2

DC24V

INPUT

1 BAUD

2 RATE

SW1