14

CX-Process Tool and Monitor

Software Specifications

CX-Process Tool and Monitor

Software Specifications

Item

Specifications

CX-Process Tool

CX-Process Monitor Plus

Name

CX-Process

CX-Process Monitor Plus

Model number

WS02-LCTC1-EV5

WS02-LCMC1-EV2

Applicable PLCs

CS-series PLCs
CJ-series PLCs

Applicable Units

CJ-series Loop-control CPU Units
CS-series Loop Control Units/Boards
CS1D Process-control CPU Units

CJ-series Loop-control CPU Units
CS-series Loop Control Units/Boards
CS1D Process-control CPU Units

Compatible com-
puters

Computer

IBM PC/AT or compatible

CPU

Intel CPU (Core, Pentium, or Celeron family)
For Windows Vista: 1 GHz min.
For any other OS: 333 MHz min. required, 1 GHz min. recommended

OS

Microsoft Windows 2000 (Service Pack 3 or higher), NT4.0
(Service Pack 6a), 98SE, Me (See note 1), XP, or Vista (Ul-
timate or Business)

Microsoft Windows 2000, NT4.0, or XP

Memory

For Windows Vista, 1 GB min.
For any other OS: 256 MB min. required, 512 MB min. rec-
ommended

Minimum:

96 Mbytes

Recommended: 128 Mbytes min.

Hard disk storage

Min. required: 350 Mbytes of free space,
Recommended: 450 Mbytes or more of free space (includ-
ing approx. 280 Mbytes used by communications middle-
ware)

Minimum: 650

Mbytes

free

space

(Including approximately 50 Mbytes used for
communications middleware and other purpos-
es)

Monitor

Minimum: XGA
Recommended: SXGA 65,536 colors or more

Minimum requirement: XGA
(XGA or above recommended)

CD-ROM drive

1 drive min.

Sound board

---

1

Mouse

Recommended: Microsoft mouse or compatible pointing device

Communications
method

Connection with CPU Unit
(or Serial Communica-
tions Board/Unit)

When FinsGateway Serial Unit driver is used:
Communications protocol with PLC: Host Link or Peripheral Bus (See note 2.)

Connect the computer to the peripheral port or built-in RS-232C port of the CPU Unit, or to the

RS-232C port of the Serial Communications Board/Unit.

Connecting cable:

For connecting to peripheral port of CPU Unit: CS1W-CN

@@@ (2 m or 6 m)

For connecting to RS-232C port of CPU Unit: XW2Z-

@@@-@ (2 m or 5 m)

When CX-Server is used:
Communications protocol with PLC: Host Link or Peripher-
al Bus
Connecting Cable:

For connecting to peripheral port of CPU Unit:

CS1W-CN

@@@ (2 m or 6 m)

For connecting to RS-232C port of CPU Unit:
XW2Z-

@@@-@ (2 m or 5 m)

CX-Server is not supported.

Connection via Controller
Link

When FinsGateway Controller Link driver or CX-Server is used:
Install the software in a computer with a Controller Link Support Board to communicate with a PLC with a
Controller Link Unit mounted.

Connection via Ethernet

When FinsGateway ETN_UNIT driver or CX-Server is used:
Install the software in a computer with an Ethernet Board to communicate with a PLC with an Ethernet Unit
mounted.