29

Ordering Information

Special I/O Units

Isolated-type Thermocouple Input Units

Note: 1. The accuracy depends on the sensors used and the measurement temperatures. For details, refer to the user’s manual.

2. This is for an external power supply, and not for internal current consumption.

3. L and

−100°C or less for K and T are ±2°C±1 digit max., and 200°C or less for R and S is ±3°C±1 digit max. No accuracy is specified for

400

°C or less for B.

Isolated-type Resistance Thermometer Input Units

Note: This is for an external power supply, and not for internal current consumption.

Isolated-type DC Input Unit

Note: This is for an external power supply, and not for internal current consumption.

Unit

classi-

fica-

tion

Product

name

I/O

points

Signal

range

selec-

tion

Signal

range

Conver-

sion speed

(resolution)

Accuracy at

ambient

temperature

of 25

°C)

External

connec-

tion

No. of

unit

num-

bers
allo-

cated

Current

consump-

tion (A)

Model

Standards

5 V

24 V

CJ1
Spe-
cial I/O
Units

Process
Input
Units
(Isolated-
type
Thermo-
couple
Input
Units)

2 in-
puts

Set
sepa-
rately
for
each
input

Thermocou-
ple: B, E, J,
K, L, N, R, S,
T, U,
WRe5-26,
PLII

DC voltage:
±100 mV

Conversion
speed:
10 ms/
2 inputs,
Resolution:
1/64,000

Standard
accuracy:
±0.05% of F.S.
(See note 1.)

Remov-
able termi-
nal block

1

0.18 0.06

(See
note
2.)

CJ1W-
PTS15

UC1, CE

4 in-
puts

Com-
mon
inputs

Thermocou-
ple: R, S, K,
J, T, L, B

Conversion
speed:
250 ms/
4 inputs

Accuracy:
±0.3% of PV
or ±1

°C,

whichever is
larger, ±1 digit
max.
(See note 3.)

0.25 ---

CJ1W-
PTS51

Unit

classi-

fica-

tion

Product

name

I/O

points

Signal

range

selec-

tion

Signal range

Conver-

sion speed

(resolution)

Accuracy at

ambient

temperature

of 25

°C)

Exter-

nal

con-
nec-

tion

No. of

unit

num-

bers
allo-

cated

Current

consump-

tion (A)

Model

Standards

5 V

24 V

CJ1
Spe-
cial I/O
Units

Process
Input
Units
(Isolated-
type
Resis-
tance
Ther-
mometer
Input
Units)

2 in-
puts

Set
sepa-
rately
for
each in-
put

Platinum resis-
tance thermom-
eter: Pt100,
JPt100, Pt50,
Ni508.4

Conversion
speed:
10 ms/
2 inputs,
Resolution:
1/64,000

Accuracy:
±0.05% of F.S.
or ±0.1

°C,

whichever is
larger.

Remov-
able
termi-
nal
block

1

0.18 0.07

(See
note.)

CJ1W-
PTS16

UC1, CE

4 in-
puts

Com-
mon
inputs

Platinum resis-
tance thermom-
eter: Pt100,
JPt100

Conversion
speed:
250 ms/
4 inputs

Accuracy:
±0.3% of PV
or ±0.8

°C,

whichever is
larger, ±1 digit
max.

0.25 ---

CJ1W-
PTS52

Unit

classi-

fica-

tion

Product

name

I/O

points

Signal range

Conver-

sion speed

(resolution)

Accuracy at

ambient

temperature

of 25

°C)

External

connec-

tion

No. of

unit

num-

bers
allo-

cated

Current

consump-

tion (A)

Model

Standards

5 V

24 V

CJ1
Special
I/O
Unit

Isolated-
type DC
Input
Unit

2 in-
puts

DC voltage:
0 to 1.25 V,

−1.25 to 1.25 V,
0 to 5 V, 1 to 5 V,

−5 to 5 V,
0 to 10 V,

−10 to 10V,
±10-V select-
able
DC current:
0 to 20 mA,
4 to 20 mA

Conversion
speed:
10 ms/
2 inputs,
Resolution:
1/64,000

Accuracy:
±0.05% of F.S.

Remov-
able
terminal
block

1

0.18 0.09

(See
note.)

CJ1W-
PDC15

UC1, CE