beautypg.com

Omega Engineering OMEGASCOPE OS533 User Manual

Page 58

background image

Specifications

7

(Specifications are for all models except where noted)

THERMOMETER
Measuring:

OS530HR,

-22°F to 250°F (-30°C to 121°C)

Temperature

OS531:

0°F to 750°F (–18°C to 400°C)

Range:

OS530L,

OS533,OS532: 0°F to 1000°F (–18°C to 538°C)

OS534

0°F to 1600°F (–18°C to 871°C)

OS523

0°F to 2500°F (–18°C to 1371°C)

OS524

1000°F to 4500°F (538°C to 2482°C)

OS531:

±2% of reading or

3°F whichever is greater

All others

±1% of reading or

3°F whichever is greater

(2% Rdg for temp > 2000°F for OS524)

Field of Vision:

OS531, OS532, OS530L

10:1

OS533, OS530HR

20:1

OS534

30:1

OS53x-CF

.15"@6"

OS523-1

30:1

OS523-2

60:1

OS523-3

68:1

OS524

110:1

Repeatability:

± (1% rdg + 1 digit)

Resolution:

1°F or 1°C (0.1°F or °C for OS530HR)

Response Time:

250 msec

Spectral Response:

8 to 14 microns (2 to 2.5 microns, OS524)

(5 to14 microns, OS530L, OS531, OS532)

Thermocouple Input

Type K, 0 to 1600°F (-18 to 871°C)

(OS532, OS533, OS534 only)

Input Connection

SMP Connector

Thermocouple Display

±5°F (±3°C)

Accuracy @ 75°F (24°C)

Ambient Temperature
Thermocouple Display

Response Time

2 seconds

Operating Ambient

32°F to 122°F

Temperature:

(0°C to 50°C)

Operating Relative Humidity: 95% or less without condensation
Display:

Backlit LCD dual display

Keypad:

4 position, tactile feed-back membrane switch

7-1

Accuracy (24°C or 75°F

Ambient Temperature and at

emissivity of 0.95 or greater):