66
Example Application
Section 3-9
3-9-3
Step 3. Transfer the CPU Bus Unit Setup Settings
Select Transfer to PLC from the Options Menu and click the Yes Button. The
settings will be transferred to the CPU Bus Unit Setup Area in the CPU Unit.
3-9-4
Step 4. Send Remote Mail Commands
Send e-mails containing remote mail commands to the Ethernet Unit.
Reading Data from a
CPU Unit Data Area
Example)
In this example, 10 words of data are read from words D00100 to D00109 and
converted to a file called D00100.CSV.
Backing Up the CPU
Unit's User Program
in the Memory Card
Example)
In this example, the CPU Unit's user program is backed up in a file called
USER.OBJ.
Receive Command
Setting
Receive specified commands
only
Selected
FileWrite
Not selected
FileRead
Selected
FileDelete
Not selected
FileList
Selected
UMBackup
Selected
PARAMBackup
Selected
IOMWrite
Not selected
IOMRead
Selected
ChangeMode
Not selected
ErrorLogRead
Selected
ErrorLogClear
Selected
MailLogRead
Selected
MailLogClear
Selected
Test
Selected
FinsSend
Not selected
Item name
Example
Subject: IOMRead
Body: Para1:38
Para2:D_100
Para3:10
Para4: D00100.CSV
Attached file: None
Subject: UMBackup
Body: Para2:USER.OBJ
Attached file: None