Parameter

Value

Description

TCP send buffer

4,096 bytes

Maximum capacity of the TCP send buffer

TCP receive buffer

4,096 bytes

Maximum capacity of the TCP receive buffer

UDP send buffer

9,000 bytes

Maximum capacity of the UDP send buffer

UDP receive buffer

9,016 bytes

Maximum capacity of the UDP receive buffer

RAW send buffer

2,048 bytes

Maximum capacity of the RAW send buffer

RAW receive buffer

2,048 bytes

Maximum capacity of the RAW receive buffer

FINS receive buffer

16,383 bytes

Maximum capacity of the FINS receive buffer

Hold timer

75 s (12 min max.)

The hold timer is used for active open processing of TCP sockets. A
ETIMEDOUT error will occur if connection is not completed within 75 s.

Resend timer

Initial value:

1 s

Maximum value: 64 s

The resend timer is used to monitor completion of reception of arrival
confirmations when transferring data via socket services, including FTP
server and mail transfer TCP sockets. If the timer setting is exceeded
before arrival confirmation is received, data is resent. Resends are per-
formed from the first timeout (1 s) through the 12th timeout (64 s). A
ETIMEDOUT error will occur after the 12th timeout.

Continue timer

Initial value:

5 s

Maximum value: 60 s

The continue timer starts if preparations have been completed to send
data but the send window is too small (either 0 or too small) to send the
data and the remote node has not requested that communications be
restarted. Confirmation of the window size is requested from the remote
node when the continue timer times out. The initial value of the timer is
5 s and confirmation processing will continue consecutively with increas-
ingly longer times until the maximum time of 60 s is reached.

2MSL timer

60 s

The 2MSL timer starts at the TCP socket that first closes the socket and
will run for 60 s in the TIME_WAIT status.

IP reassemble timer

12 s

A fragmented IP packet is discarded if it cannot be reassembled within 12
seconds.

ARP timer

20 min/3 min

If a complete ARP table entry (with an Ethernet address) is not referred
to for 20 minutes, it is removed from the table.

An incomplete ARP table entry (no response yet returned to the ARP
request) is removed from the table after 3 minutes.

Window size

4,096 bytes

The initial value of the maximum capacity used to control the conver-
gence of TCP sockets. Actually, the node negotiates with the remote
node and uses the smaller of the values for the two nodes. The window
size will fluctuate with the available space in the TCP reception buffers of
the remote node when processing communications.

Fragment size

1,500 bytes

UDP data is separated into 1,472-byte fragments. The remaining
28 bytes are for the IP header.

Segment size

1,024 bytes

TCP data is separated into 1,024-byte units, unless the segments are dif-
ferent, in which case it will be separated into 536-byte units.

TTL (Time to Live)

30

Decremented each time an IP router is passed.