beautypg.com

5 breakpoint: bp – Renesas HS2378KCI01H User Manual

Page 130

background image

106

5.2.5

BREAKPOINT: BP

Description:

Sets software breakpoints.

Note:

The function will be different according to the MCUs used.

Format:

bp

Table 5.6 BREAKPOINT Command Parameter

Parameter

Type

Description

Numerical value,
character string

Breakpoint value set by numerical value or symbol

When an odd address is set, the address is rounded down to
an even address.

Note: The parameters for this command vary with the product. For the specifications of

each product, refer to the on-line help.

Examples:

To set a software breakpoint at address H'12c8:

>

bp H'12c8 (RET)