The command list of the E10A emulator is shown below.

Table 5.1 E10A HDI Commands

No

Command

Abb.

Function

1

BREAKCONDITION_
CLEAR

BCC

Clears hardware breakpoints that have been set.

2

BREAKCONDITION_
DISPLAY

BCD

Displays hardware breakpoints that have been set.

3

BREAKCONDITION_
ENABLE

BCE

Enables or disables hardware breakpoints that have
been set.

4

BREAKCONDITION_
SET

BCS

Sets hardware breakpoints.

5

BREAKPOINT

BP

Sets software breakpoints.

6

BREAKPOINT_CLEAR

BC

Clears software breakpoints that have been set.

7

BREAKPOINT_DISPLAY

BD

Displays software breakpoints that have been set.

8

BREAKPOINT_ENABLE

BE

Enables or disables software breakpoints that have
been set.

9

DEVICE_TYPE

DE

Displays MCU type currently selected.

10

GO_OPTION

GP

Sets or displays the emulation mode during user
program execution.

11

JTAG_CLOCK

JCK

Displays or sets a JTAG clock (TCK) frequency.

12

REFRESH

RF

Updates the HDI memory information to the latest
contents.

13

RESET

RE

Resets the H8S/xxxx.

14

STATUS

STS

Displays emulator status information.

15

STEP_INTERRUPT

SI

Sets or displays the enable or disable status of

interrupts during step execution.

16

TRACE_DISPLAY

TD

Displays acquired trace information.

Note: Support for these commands varies with the product. For the specifications of each

product, refer to the on-line help.