beautypg.com

Pre l iminar y – Runco SC-1 User Manual

Page 107

background image

Maintenance and Troubleshooting

Runco SC-1 Owner’s Operating Manual

95

PRE

L

IMINAR

Y

Power and Cooling

40

Lamp has shut down due to fan failure.

46

Red DMD heat sink overheated.

47

Green DMD heat sink overheated.

48

Blue DMD heat sink overheated.

49

Prism overheated.

4C

Projector shutdown due to critical error.

4D

Integrator has overheated.

4E

Inadequate lamp air intake rate (interlock)

4F

Inadequate air exhaust rate (interlock)

53

Fan 3 has failed (side [rear] intake fan).

54

Fan 4 has failed (side [front] intake fan).

55

Fan 5 has failed (lamp exhaust fan).

56

Fan 6 has failed (LAD fan).

57

Fan 7 has failed (card cage fan).

58

Fan 8 has failed (heat exchanger fan — for liquid cooling system).

TIPM (Image Processor)

60

Boot code CRC failed.

61

Unable to program DigMux PLD.

62

Unable to program Control PLD.

63

Unable to program Bubks PLD.

64

Unrecognized ROM type.

65

Write to flash ROM failed.

66

General TIPM failure.

67

Downloaded code will not fit into ROMs.

68

Communication error with scaler on TIPM.

Built-In Keypad

70

Unable to access EEPROM on the built-in keypad.

71

EEPROM memory re-initialization on the built-in keypad.

Table 5-2. SC-1 Error Codes (continued)

Code

Description

Note: To clear a system error, press the EXIT key (on the SC-1 control panel) twice. If necessary,
reset the projector by powering it off, allowing it to cool and powering it on again. Contact your
Runco dealer or Runco technical support if the error persists.