Low voltage high voltage – Raypak XPAK 85 User Manual
Page 36
36
REMOTE CONTROL EXTERNAL
SENSOR
0T+
M4
-t°
M2
TANK
THERMOSTAT
V
ROOM
THERMOSTAT
(jumper when
not used)
TANK
SENSOR
-t°
M4a
M3b
M3a
M3
UNDERFLOOR HEATING LIMIT
THERMOSTAT OR
CONDENSATE PUMP ALARM
(jumper when not used)
LOW VOLTAGE
HIGH VOLTAGE
120V
N
L
F=
fuse 4AF
PCB fuse=4AT
Cod. 20003227
3W
BLUE (COMMON)
BR
O
WN (CLOSED)
BLA
CK(OPEN)
Fig. 35
11. TERMINAL STRIP DETAILS
Terminal
Description
Technical
Indications
strip
specifications
reference
M3
Main supply
120 VAC – 60 Hz
The main supply cable must be anchored to the
boiler frame (Fig. 39) and pass through the
strains relief (field supplied). Cable as specified in
the electrical supply.
M3a
3-way valve:
Connections for DHW
Model: Honeywell VC6011 (actuator) + VCZMK6000
external 3-way valve
120 VAC – 60 Hz
(Cartridge valve)
The 3-way valve cable must be anchored to the boiler
frame (Fig. 39) and pass through the strains relief (field
supplied) (Fig. 39). Cable as specified in the electrical
supply.
M4
Outdoor sensor
12 K Ohm B3760
M4
Remote control
Open therm plus protocol
Only Raypak Part No. 013073
M4a
Room thermostat
24 VDC
Volt free (Jumper when not used)
M4a
Tank sensor
10 K Ohm B3435
Immersion type.
for DHW
If the boiler is installed with a tank sensor, the Jumper
on the PCB must be in position 2 (Fig. 61)
M2a
Tank thermostat
On/off (NO)
Volt free
for DHW
If the boiler is installed with a tank termostat, the
Jumper on the PCB must be in position 3 (Fig. 61)
M3b
Under-floor heating limit
On/off (NC)
Volt free.
thermostat and condensate
This is a generic input to lock out the boiler. Jumper when
(generic available alarm) not used). If the contact will be
open the alarm number 21
will appear on the display and the boiler is lock out
High voltage (Fig. 35)
Low voltage (Fig. 35)
Tab. 9