Raypak H7 504-2004 User Manual

Mvb™ - type h

background image

Catalog No.: 2000.364A

Effective: 8-15-07

Replaces: 6-15-07

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

84% Thermal Efficiency at Full Rate

100% Factory Fire Tested

Maximum Outlet Water Temperature: 220°F

Minimum Acceptable Inlet Water Temperature: 120°F

Full Safety Diagnostics with History

Footprint: Less Than 5-1/2 ft

2

Limited Twenty-Year Thermal Shock Warranty

Limited Ten-Year Heat Exchanger Warranty

Electronic Modulation, Constant Ratio 1.4:1 Turndown

TempTracker Mod Controller with LCD Display

Status Display Lights

Heat Exchanger
ƒ Bronze Headers
ƒ ASME H Stamped

160 PSIG Working Pressure

ƒ National Board Approved
ƒ Fin Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ ASME Powder-Coated Tube Sheet
ƒ Silicone High Temp O-Rings
ƒ ASME Pressure Relief Valve

60 PSIG – Standard
PSIG – Optional

ƒ Temperature and Pressure Gauge,

Shipped Loose

ƒ Stainless Steel Evaporator Plate

Control
ƒ 120V, 60Hz, 1Ø, Power Supply
ƒ 120/24V 60Hz Transformer
ƒ Ignition Module

3-Try – Standard
Single-Try – Option C-6

ƒ Hot Surface Ignition (HSI)
ƒ Remote Flame Sensor
ƒ High Limit, Manual Reset, Fixed,

240ºF

ƒ On/Off Power Switch
ƒ Flow Switch
ƒ Blocked Vent Pressure Switch
ƒ Combustion Air Proving Switch
ƒ Pump Switch
ƒ Pump Time Delay
ƒ Diagnostics Panel
ƒ Modulating Temperature Control
ƒ Water Temperature Sensors (3)

Burner
ƒ Ultra-Low NOx: Less than 20 PPM

Gas Train
ƒ Fuel

Natural Gas
Propane

ƒ Zero Governor Regulator
ƒ Dual-Seat Combination Valve
ƒ Electronic Modulating Firing Mode

Construction
ƒ Indoor/Outdoor Construction
ƒ Front Controls Enclosed
ƒ PolyTuf Powder Coat Finish
ƒ Rear Connections (Water, Electrical,

Gas, Vent, Combustion Air)

ƒ Design Certified ANSI Z21.13/

CSA 4.9

Venting
ƒ Vent Termination Cap

Outdoor - Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)

ƒ Combustion Air

In-Line Filter Kit – Option D-17
Air Intake Elbow – Option D-16

ƒ Extractor – Optional

By others
Not required


Temperature Controllers

B-36 Temp-Tracker Mod+ Digital

Controller, Up to 4 Boilers,
OA Reset

B-37 Temp-Tracker Mod+ Digital

Controller, Up to 10 Boilers,
OA Reset

B-38 Temp-Tracker Mod+ Digital

Controller, Up to 16 Boilers,
OA Reset

Y-241 Electronic Sequencer,

Up to 4 Boilers

Y-281 Electronic Sequencer,

Up to 8 Boilers

Options

A-13 Air Vent, Auto, 150 PSI
F-10 Low Water Cut-Off, Remote Probe
I-1

High Limit, Auto Reset, Adj.,
100-240

°F

I-2

High Limit, Manual Reset, Adj.,
100-240

°F

P- Pump: HP, 120V, 1

∅, 60Hz

Water Hardness: GPG

Cast Iron

Bronze

Loose

Mounted

P- Cold Water Start
P- Cold Water Run
S-1

Low Gas Pressure Switch,
Manual Reset

S-2

High Gas Pressure Switch,
Manual Reset

Regulatory Agency Requirements

MVB™ - Type H

Heating/Hot Water Supply Boilers

Models H7 504-2004