Chapter 6. Troubleshooting

6.1 Flowchart to Remedy the Troubles

Figure 6.1 shows the flowchart to remedy the troubles from when power to the emulator is activated
until the emulator debugger starts up. Check this while the target system is disconnected.

For the latest FAQs, visit the Renesas Tools Homepage.

http://www.renesas.com/en/tools

Figure 6.1 Flowchart to remedy troubles

LED not normal

Not normal/Error displayed

Turning on the power of PC4701

Program window of emulator debugger displayed

Front panel LED of

PC4701

Init dialog box of emulator

debugger displayed

1. Check the operating environment etc. of the emulator

debugger.

See the user's manual of the emulator debugger.

2. Reinstall the emulator debugger.

1. Check emulator system connections.

See, "3.6 Connecting the PC4701" (page 41).

2. Redownload the firmware.

See "4.2 Downloading Firmware" (page 48).

3. Restart the PC4701 system.

Error displayed

See "6.2 (2) Errors Occur When the Emulator Debugger Starts
Up (When the target system is connected) (page 68).

See "6.2 (3) Errors Occur When the Emulator Debugger Starts
Up (When the target system is not connected) (page 69).