2.7.2 If an Error is Detected in the Self-check
Table 2.4 lists how to remedy the troubles if the target status LED display is abnormal in the self-check. When an error is
detected, shut off the emulator and the user system and follow the steps in the Table 2.4.

Table 2.4 Error display in the self-check and how to remedy it

LED display

Blinking

OFF

POWER CLOCK RESET RUN

Problem & Remedy

The emulator system is not working properly.
- Check that power is supplied to the emulator.
- The emulator may be damaged. Contact your local distributor.

A clock is not supplied to the emulator.
- Check that the oscillator circuit board (OSC-2) is attached.
- Check that the oscillator or oscillation module on an oscillator circuit board (OSC-2) is

operating normally.

The MCU is not controlled properly.

- Check that the MCU is mounted properly
- Check that the oscillation frequency of the oscillator circuit board (OSC-2) is within

the MCU specifications.

Others

The emulator system is not working properly.
- The emulator may be damaged. Contact your local distributor.

IMPORTANT

Notes on the Self-check:

Be sure to disconnect the user system before executing the self-check.
Use the preinstalled oscillator circuit board OSC-2 (6 MHz) to execute the self-check.

If the self-check does not result normally (excluding target status errors), the emulator may be damaged. Then,
contact your local distributor.