2. Setup

REJ10J0972-0100 Rev.1.00 February 10, 2006

Page 29 of 72

2.7 Self-check


2.7.1 Self-check Procedure
To run the self-check of the emulator, do so as explained here below. While the self-check is in progress, the LEDs will change
as shown in Figure 2.9.

(1) If the user system is connected, disconnect it.
(2) Set the switches as the factory-settings to execute the self-check (see Table 2.3).
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator upper panel.
(4) Check the SAFE LED starts flashing and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 10 seconds, the self-check terminated normally.

Table 2.3 Switch settings for the self-check

Switch Setting

MCU power supply voltage selection swtich (SW1)

5V


Figure 2.9 Self-check procedure

POWER

CLOCK

RESET

RUN

LED3

LED4

LED5

LED6

RESET

(1 ) Within 2 seconds of activating power ,

press the reset switch .

(2 ) Check that the SAFE LED starts

blinking , then press the system reset

switch again .

(3 ) Target status LEDs start blinking at random intervals .

Normal

RESET

ON

Blinking

It takes 10 seconds at XIN = 4 MHz.

POWER

CLOCK

RESET

RUN

LED3

LED4

LED5

LED6

POWER

CLOCK

RESET

RUN

LED3

LED4

LED5

LED6

LED1

LED2

POWER

SAFE

POWER

CLOCK

RESET

RUN

LED3

LED4

LED5

LED6

LED1

LED2

POWER

SAFE

LED1

LED2

POWER

SAFE

Error

POWER

CLOCK

RESET

RUN

LED3

LED4

LED5

LED6

Self- check starts.

SAFE LED status

ON

OFF

Blinking

SAFE LED is turned off and one or more target status

LEDs start blinking according to the error type .

LED display

LED1

LED2

POWER

SAFE

LED1

LED2

POWER

SAFE

OFF