L676 Direct Vent Gas Fireplace

9

INST

ALLA

TION

INSTALLATION

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in accordance with these instructions.

Clearance to Combustibles from:

Back 0"

(0mm)

Side 0"

(0mm)

Floor 0"

(0mm)

Minimum Clearance from Top of Front Facing:

Mantel min. 16-1/2"

(419mm)

Ceiling

52"

(813mm) from top of front facing

Side Wall to Unit:

15"*

(381mm)

Horizontal Vent Clearances to Combustibles:

Top

3" (76mm)

Side

2" (51mm)

Bottom

2" (51

mm)

Vertical Vent Clearances to Combustibles:

All Sides 2"

(51mm)

Alcove Clearances:

Min. Depth 36"

(914mm)

Min. Width* 84"

(2134mm)

Min. Height 84"

(2032mm)

* Alcove side wall must have a minimum of 15" (381mm) clearance on one side.

Caution Requirements

The top, back and sides of the fi replace are defi ned by

standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials
are not adhered to. It is of greatest importance that this

fi replace and vent system be installed only in

accordance with these instructions.

IMPORTANT

If converting this unit to LP, it is highly recommened
the conversion be done BEFORE the unit is slid into

position for ease of conversion. See "Conversion

from NG to LP" section for instructions.