beautypg.com

Installation, Log set installation, Inst alla tion – Regency Liberty L676 User Manual

Page 36

background image

Regency

®

L676 Direct Vent Gas Fireplace

36

INST

ALLA

TION

LOG SET INSTALLATION

Installation of Interior Brick Panels must be completed before installing the log set.

Read the instructions below carefully and refer to the diagrams.
If the logs are broken do not use the unit until they are replaced.
Broken logs can interfere with pilot operation.

Log kit (Part No. 521-930 and 521-935) contain the following pieces:

a) 03-25 Log

Rear

b) 03-26 Log

Top

c) 03-27 Log

Front

Left

d) 03-28 Log

Front

Right

e)

902-154 Embers

Lava

f) 902-179 Vermiculite

1)

Carefully remove the logs from the box and unwrap them. The logs

are fragile, handle with care - do not force into position.

2)

Place log 03-25 on the rear log support pins.

The "03" reference numbers (i.e. 03-25) are

molded into the rear of each log.

3)

Place log 03-27 on the front left side of the burner. Place the right

end of the log into the pin and rest the left end of the log inbetween
the rear and front burner tubes.

03-28

03-26

03-27

03-25

03-25

03-27

4)

Place the left end of log 03-28 into the pin while resting the right end

of the log on the grate. Slide the right end of the log forward until it
is approximately 3/8" away from the back side of the grate.

03-28

Rear
Burner
Tube

Front Burner Tube

Backside of Grate

5)

Line up the two holes on the underside of log 03-26 with the pins on

logs 03-25 and 03-27 and fi t in place.

03-26

03-27

03-25

INSTALLATION