33

INST

ALLA

TION

25)

Remove the pilot shield by removing the 2
screws.

26)

Remove the clip from the pilot head assembly

using a fl at head screw driver.

27)

Remove the NG pilot orifi ce with the Allen

Key and replace with LP pilot orifi ce.

28)

Re-install the pilot head and pilot shield.

Pilot

Shield

Clip

29)

Using a Torx T20, remove and discard the
3 pressure regulator mounting screws.
Remove the modulator coil and the
gasket.

30)

Ensure that the new rubber gasket (supplied
with coil) is properly positioned and install the
new modulating pressure regulator assem-
bly to the valve using the screws supplied
with the kit. Tighten screws securely.

31)

Install the enclosed identifi cation label to the
valve body where it can be easily seen.

32) Attach the LP conversion decal near or

on top of the serial no. decal.

33)

Replace yellow "Natural Gas" label with red

"Propane" label.

34)

Re-install valve tray and all electrical

connections to the valve and solenoid
valve.

35)

Cut the cable tie that holds the wires

connected to the Control Module and pull
out.

Note:

An extra cable tie is included with

the LP Kit for re-installation.

Cable Tie

Control Module

36)

Remove the J9 jumper using needle nose
pliers.

37)

Re-install the control module.

38)

Re-install the base brick panel.

39)

Re-install the rear log support bracket.

40)

Plug in the power source.

41)

Re-install the left heat shield.

42)

Install the interior brick panels.

43)

Adjust the burner aeration settings to the LP

settings and install the burners.

Front

Burner 5/16"

Rear

Burner 1/4"

44)

Re-install the grate.

45)

Turn on the gas supply and check for gas

leaks.

46)

Install the log set.

47)

Re-install the glass door.


48)

Check the inlet (12" WC) and outlet
(10"WC).

49)

Re-install the right heat shield.

50)

Check operation of fl ame control using
the remote control. Refer to FireWizard
operation manual for details.

51)

Check for proper fl ame appearance.

52)

Install the exterior brick panels.