beautypg.com

4 serial i/o interface, Figure 2.4 serial i/o interface – Renesas 32185 User Manual

Page 50

background image

32185/32186/32192/32195/32196 Group

Starter Kit User’s Manual M3A-2154G52B

REJ10B0223-0150/Rev.1.50

Mar 2008

Page 42 of 80

2.4 Serial I/O Interface

The evaluation board is interfaced to the host PC (Windows) through its RS-232C by using SIO of
the M32R/ECU. Of the RS-232C control signals, only TXD and RXD are used for connection to the
host PC (Windows). The unused CTS and RTS are directly-coupled to configure a loop-back. The
unused DSR and DTR also are configured in a similar manner.
The serial I/O interface is configured in such a way that only one serial I/O channel can be used at a
time.
Any of the four channels 0–3 can be selected using a rotary switch.

A

TXD

RXD

RXD0

RXD1

RXD2

RXD3

TXD0

TXD1

TXD2

TXD3

P82/TXD0/TO26

P85/TXD1/TO23

P174/TXD2/TO28

P83/RXD0/
TO25

3

1

2

J15

2

J18

P86/RXD1/TO22

2

J19

P175/RXD2/TO27

J20

P75/RTDRXD/
RXD3/NBDD1

3

1

2

3

1

3

1

U1
M32R/ECU

P74/RTDTXD/
TXD3/NBDD0

TXD

RXD

DSR

DTR

RTS

CTS

P83

P175

P86

P82

P174

P85

P74

P75

NBDD0

NBDD1

Y1

Y0

Y2

Y3

C

B

U9
MAX3232CSE+

CN5
XM2C-0912

U8
QS21X384Q1G

U7
TC74VHC138FT

CN4
XG4C-1434

SW2
DR-KR10H

CON2
FX1-144S-1.27DS

CON1
FX1-144S-1.27DS

* CNx,CONx : Connector
* Jx : Jumper
* SWx : Switch
* Ux : IC


Figure 2.4 Serial I/O Interface

This manual is related to the following products: