beautypg.com

2 fp select circuit – Renesas 32185 User Manual

Page 48

background image

32185/32186/32192/32195/32196 Group

Starter Kit User’s Manual M3A-2154G52B

REJ10B0223-0150/Rev.1.50

Mar 2008

Page 40 of 80

2.2 FP Select Circuit

The FP select circuit is used for reprogramming the internal flash memory of the M32R/ECU.
This circuit is configured in such a way that FP is switched from the EXTFP signal of extension
connector (CON2) by using a jumper (J10).


J10

U1
M32R/ECU

TX14

FP

1

3

2

VCCE

EXTFP

CON2
FX1-144S-1.27DS

* CONx : Connector
* Jx : Jumper
* TXx : Test pin
* Ux : IC

Note: TX14 is not mounted but it only has one pattern available.


Figure 2.2 FP Select Circuit

Table 2.2 FP Select Circuit (Jumper)

Name Condition

Description

Shorted

between 1–2

Default

Enables reprogramming the mounted M32R/ECU’s internal flash

Shorted

between 2–3

Disables reprogramming the mounted M32R/ECU’s internal flash

J10

Open

Unusable

Note: The J10 jumper is shorted by pattern wiring on the reverse side of printed circuit board.

Case of setting the condition except for default, setting the jumper is required after cutting the pattern
for default condition by referring to the chapter 3.8 Setting jumper by cutting pattern.

This manual is related to the following products: