8.5 Air Cooling System 

The  sensing  head  can  operate  in  ambient  temperatures  up  to  200°C 
(392°F)  with  the  air‐cooling  system.  The  air‐cooling  system  comes 
with a T‐adapter including 0.8 m / 31.5 in (optional: 2.8 m / 110 in) air 
hose and insulation. The T‐adapter allows the air‐cooling hose to be 
installed without interrupting the connections to the box. 
The air‐cooling jacket may be combined with the right angle mirror. 

Figure 35: Air Cooling System 

 

Figure 36: Connecting the T‐Adapter (XXXMIACCJ) 

max. ambient 200°C (392°F)

Sensing Head

max. ambient 50°C (122°F)

Air Hose

T-

Adapter

Electronic

Housing

Cable

Air cooling (max. 35°C / 95°F)

Hose to
sensing head

T-Adapter

Cable to electronic
housing

Fitting free for air connection
Hose:
inner Ø: 9 mm (0.35 in)
outer Ø: 12 mm (0.47 in)