Non-Standard Tier Configuration
Guidelines for Existing Firmware Versions
•
Non-Standard tier configurations are those configurations supported by Paragon II, but require special
procedures in order to function properly. These include:
−
Triangle Configuration
−
Diamond Configuration
−
Redundant Configuration
•
When a Non-Standard tier configuration is detected, Paragon will do the following:
−
Display the message “Illegal Connect/Check CTxxxxxx” on the LCD panel, where CTxxxxxx is
the serial number of UMT that has the Non-Standard configuration on its user ports
−
Stop normal function and continue displaying the message until the connection is removed and the
unit is reset
−
While the UMT is trapped on the message, it will send the broadcasting message to all UST1s
every two (2) seconds, “Illegal connection on CTxxxxxx”
−
The message will also appear on the OSD until the Non-Standard tier configuration is removed
•
Recovery:
−
After any re-connection subsequent to the Non-Standard tier configuration, all UMT Matrix
Switches should undergo a FUNC reset to clear the switch database. This procedure should be
performed starting from the third tier device down to the base unit.
−
Whenever a third tier UMT Matrix Switch is replaced, all of the second tier and base UMT Matrix
Switches should undergo a FUNC reset.
−
Whenever a second tier UMT Matrix Switch is replaced, all of the base UMT Matrix Switches
should undergo a FUNC reset.
−
Whenever a base UMT Matrix Switch is replaced, only the new UMT Matrix Switch should
undergo a FUNC reset.