Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

16-1/2”

(419mm)
Minimum

4"

(102mm)

3"

(76mm)

1-1/2"

(38mm)

30”

(762mm)

10" (254mm)

dia. Hole through

wall for Dura-Vent

1/2"
(13mm)
Drywall

Top Header

Opening for gas

connection

INSTALLATION

3) For exterior walls, insulate the enclosure to

the same degree as the rest of the house,
apply vapour barrier and drywall, as per lo-
cal installation codes. (Do not insulate the
fi replace itself.)

4) The top of the unit must not be closer than

30" (762mm) to the ceiling.

5) Combustible material may be brought up to

the top and sides of the unit and be covered
with ceramic tiles, bricks, rock or other suit-
able combustible fi nishing materials.

Note: The unit does not have to be complete-

ly enclosed in a chase. The clearance
on top of the unit is 0" to the standoffs
so combustible building materials can
be laid directly on top of the standoffs.
You must maintain clearance from the
vent to combustible materials for fl ex
for Simpson Dura-Vent, see page 7.

1) Determine the total thickness of facing

material (e.g. drywall plus ceramic tiles) to
allow the fi nished surface to be fl ush with
the front of the unit. Total facing thickness
can vary from 1/2" (13mm) to 1-1/4" (32mm)
thick.

6) Use steel studs for framing where the

1-1/2" (38mm) clearance from the vent
to combustible material cannot be main-
tained.

2) Frame in the enclosure for the unit with

framing material.

Vertical Termination or

Vertical Rise with Horizontal

Termination

Rear Termination

FRAMING AND FINISHING

NOTE: If this is an outside corner, the
minimum distance between the vent and the
outside corner is 6" (15cm) with AstroCap
termination cap or 12" (30cm) with Dura-Vent
termination cap.

NOTE: If this is an outside corner, the minimum
distance between the vent and the outside corner
is 6" (15cm) with AstroCap termination cap or 12"
(30cm) with Dura-Vent termination cap.

Simpson Dura-Vent Piping

Flex Piping

12-3/4”

(324mm)
Minimum

4"

(102mm)

3"

(76mm)

1-1/2"

(38mm)

26”

(660mm)

10" (254mm)

dia. Hole through

wall for Flex

1/2"
(13mm)
Drywall

Top Header

Opening for gas

connection

Simpson Dura-Vent

Minimum Clearances

Flex Pipe

Minimum Clearances

For Both Simpson & Flex

For Both Simpson & Flex

The HeatWave Duct Kit has different clear-
ance and framing requirements, check the
HeatWave manual for details.

Install Side Nailing Strips, and Top Facing
Support before unit is slipped into position.
See page 9 for assembly details.