Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

REGENCY DIRECT VENT SYSTEM (FLEX)

(Propane & Natural Gas)

This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45

o

and one 90

o

elbow (two 45

o

elbows equal

one 90

o

elbow).

Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer to page 13.)

• Maintain clearances to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.

A vent guard should be used whenever
the termination is lower than the specifi ed
minimum or as per local codes.

Note: Regency Direct Vent System (Flex) is

only approved for horizontal termina-
tions.

INSTALLATION

Minimum

Simpson Dura-Vent Center-Line

Minimum Flex Kit Center-Line

Important

If using any Cabinet Mantels with Part
# 510956, 510958, 510962, 510964
and 510834 the wall thimble must
be secured fi rst and venting must be
attached to unit before sliding into
fi nal position.

Also Simpson Dura-Vent venting can-
not be used with any of the mantels

noted above.