AERATION

ADJUSTMENT

The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue fl ame or close for a yellower
fl ame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.

Minimum Air Shutter Opening:
3/16"

Natural

Gas

3/8"

Propane

CAUTION: Carbon will be produced if air shutter
is closed too much.

OPERATING INSTRUCTIONS

4) When the pilot stays lit, turn the gas knob

further counterclockwise to the "ON" posi-

tion.

5) Use the wall switch, thermostat or remote

control to turn on the unit.

6) Rotate the fl ame height regulator to adjust

the fl ame height higher or lower.

SHUTDOWN

PROCEDURE

1) Use the wall switch, thermostat or remote

control to turn off the main burner.

2) Turn the main gas control clockwise to the

"OFF" position to turn off the pilot.

3) Turn off all electric power to appliance if

service is to be performed.

FIRST FIRE

The fi rst fi re in your stove is part of the paint cur-
ing process. To ensure that the paint is properly
cured, it is recommended that you burn your
fi replace for at least four (4) hours the fi rst time
you use it with the fan on.

When fi rst operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at this
time. Open a few windows to ventilate the room
for a couple of hours.

The glass panel may require cleaning after the
unit has cooled down. DO NOT ATTEMPT TO
CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appli-

ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.

OPERATING

INSTRUCTIONS

1) Read and understand these instructions

before operating this appliance.

2) Check to see that all wiring is correct and

enclosed to prevent possible shock.

3) Check to ensure there are no gas leaks.

4) Make sure the glass in the door frame is

properly positioned. Never operate the ap-
pliance with the glass removed.

5) Verify that the venting and cap are unob-

structed.

6) Ensure that the brick panels are installed.

7) Verify log placement. If the pilot cannot be

seen when lighting the unit, the logs have
been incorrectly positioned.

8) The unit should never be turned off, and on

again without a minimum of a 60 second
wait.

LIGHTING PROCEDURE

IMPORTANT: Gas cock knob cannot be turned
from "PILOT" to "OFF" unless it is partially
depressed.

1) Turn burner OFF using "ON/OFF" switch.

2) Turn gas control knob so indicator points to

"OFF" position and allow 5 minutes for any

gas in the combustion chamber to escape.

3) Turn gas control knob counterclockwise

so indicator points to the "PILOT" position.

Depress the gas control knob fully. Depress

the igniter button several times until the

pilot lights. After approximately one minute,

release the gas control knob. The pilot fl ame

should continue to burn. If the pilot does not

remain lit, repeat operation allowing a longer

period before releasing gas control knob.

Closed - Tall yellow

Open - Short blue

Note: Any damage due to carboning result-

ing from improperly setting the aera-
tion controls is NOT covered under
warranty.

Note: Aeration Adjustment should only be

performed by an authorized Regency
Installer at the time of installation or
service.

Adjustment Wire: push to close

or pull to open aeration cap

wire

Air

shutter

DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.

During the fi rst few fi res, a white fi lm may
develop on the glass front as part of the curing
process. The glass should be cleaned or the
fi lm will bake on and become very diffi cult
to remove. Use a non-abrasive cleaner and
NEVER clean the glass while it is hot.

IMPORTANT

To ignite or reignite the pilot,

you must fi rst release the ten-

sion springs below the door.

Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not
be operated with the tension springs
unattached.