beautypg.com

Installation – Regency P33-NG3 User Manual

Page 18

background image

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Horizontal Venting with Two (2) 90

o

Elbows

Horizontal Venting with Two (2) 90

o

Elbows

Horizontal Venting with Three (3) 90

o

Elbows

Option H

V

H + H1 + H2

A)

1 Max. 1' Min. 3' Max.

B)

2' Max. 3' Min. 5' Max.

C)

3' Max. 5' Min. 6' Max.

D)

4' Max. 7' Min. 7' Max.

E)

5' Max. 9' Min. 8' Max.

F)

6' Max. 11' Min. 9' Max.

INSTALLATION

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

Option V

H + H1

A)

1' Min. 3' Max.

B)

2' Min. 4' Max.

C)

3' Min. 5' Max.

D)

4' Min. 6' Max.

E)

5' Min. 7' Max.

F)

6' Min. 8' Max.

With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90

o

elbows

is required.

With these options, max.
total pipe length is 30 feet
with min. of 11 feet total
vertical and max. 9 feet
total horizontal.
Please note min.
1 foot between 90

o

elbows is required.

Option H

V

H + H1

A)

1' Max. 1' Min. 3' Max.

B)

2' Max. 2' Min. 5' Max.

C)

3' Max. 4' Min. 6' Max.

D)

4' Max. 6' Min. 7' Max.

E)

5' Max. 8' Min. 8' Max.

With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.

This manual is related to the following products: