beautypg.com

Installation – Regency P33-NG3 User Manual

Page 26

background image

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

Conversion Kit from Natural Gas to Propane Model #431-969

for P33-3 using SIT 820 NOVA Gas Valve

Remove the 2 screws, push Burner

Assembly to the left and lift out.

7) Unscrew the pilot orifi ce with the allen key

and replace with the LP pilot orifi ce in the
kit and replace pilot cap.

Burner Orifi ce

Conversion Kit Contains:

Qty. Part

# Description

1 910-018 SIT

Conversion

Kit-50%

Turndown LP

1 910-037

LP Injector (Pilot Orifi ce)

1 904-163

Burner Orifi ce #54

1 908-255

Decal "Converted to Propane"

1 908-528 Red

"PROPANE"

label

1 908-529 5/32"

Allen

Key

1 908-812 Instruction

Sheet

1) Shut off the gas supply.

2) Remove the louvers (and bay door if it is

installed).

3) Open the fl ush door and remove the door.

4) Remove the logs and embers/rockwool.

5) Remove the 2 screws holding the Burner

Assembly to the fi rebox base. Push the
Burner Assembly to the left and lift out.

6) Pull off the pilot cap to expose the pilot

orifi ce.

8) Remove burner orifi ce with a 1/2" wrench

and discard. Use another wrench to hold on
to the elbow behind the orifi ce.

9) Reinstall new burner orifi ce LP stamped #54

and tighten.

10) Remove and discard the 3 pressure regula-

tor mounting screws (A), pressure regulator
tower (B) and diaphragm (C).

11) Insure that the rubber gasket (D) is properly

positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.

12) Reverse steps 5) to 2).

13) Attach clear label "This unit has been con-

verted to Propane" near or on the serial #
decal. Attach white label "This valve has
been converted from NG to LPG using SIT
conversion Kit Code 0.907.202" onto the
valve.

14) Replace yellow "Natural Gas" label with red

"Propane" label

15) Check for gas leaks.

16) Check inlet and outlet pressures.

17) Check operation of fl ame control.

18) Check for proper fl ame appearance and

glow on logs.

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

This manual is related to the following products: