286 midi implementation, Global parameter control – Roland XV-5080. User Manual
Page 286
![background image](/manuals/196380/286/background.png)
286
MIDI Implementation
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
03H
Sub ID#2 (Master Fine Tuning)
llH
Master Fine Tuning LSB
mmH
Master Fine Tuning MSB
F7H
EOX (End Of Exclusive)
mm, ll : 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.9 [cents])
*
The Master Tune parameter (SYSTEM/COMMON) will change.
❍
Master Coarse Tuning
Status
Data byte
Status
F0H
7FH,7FH,04H,04H,llH,mmH
F7
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
04H
Sub ID#2 (Master Coarse Tuning)
llH
Master Coarse Tuning LSB
mmH
Master Coarse Tuning MSB
F7H
EOX (End Of Exclusive)
llH :
ignored (processed as 00H)
mmH :
28H - 40H - 58H (-24 - 0 - +24 [semitones])
*
The Master Key Shift parameter (SYSTEM/COMMON) will change.
●
Global Parameter Control
*
Not received in Performance mode and Patch mode.
❍
Reverb Parameters
Status
Data byte
Status
F0H
7FH,7FH,04H,05H,01H,01H,01H,01H,01H,ppH,vvH
F7H
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
05H
Sub ID#2 (Global Parameter Control)
01H
Slot path length
01H
Parameter ID width
01H
Value width
01H
Slot path MSB
01H
Slot path LSB (Effect 0101: Reverb)
ppH
Parameter to be controlled.
vvH
Value for the parameter.
pp=0 Reverb Type
vv = 00H Small Room
vv = 01H Medium Room
vv = 02H Large Room
vv = 03H Medium Hall
vv = 04H Large Hall
vv = 08H Plate
pp=1 Reverb Time
vv = 00H - 7FH 0 - 127
F7H
EOX (End Of Exclusive)
❍
Chorus Parameters
Status
Data byte
Status
F0H
7FH,7FH,04H,05H,01H,01H,01H,01H,02H,ppH,vvH
F7H
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
05H
Sub ID#2 (Global Parameter Control)
01H
Slot path length
01H
Parameter width
01H
Value width
01H
Slot path MSB
02H
Slot path LSB (Effect 0102: Chorus)
ppH
Parameter to be controlled.
vvH
Value for the parameter.
pp=0 Chorus Type
vv=0 Chorus1
vv=1 Chorus2
vv=2 Chorus3
vv=3 Chorus4
vv=4 FB Chorus
vv=5 Flanger
pp=1 Mod Rate
vv= 00H - 7FH 0 - 127
pp=2 Mod Depth
vv = 00H - 7FH 0 - 127
pp=3 Feedback
vv = 00H - 7FH 0 - 127
pp=4 Send To Reverb
vv = 00H - 7FH 0 - 127
F7H
EOX (End Of Exclusive)
❍
Channel Pressure
Status
Data byte
Status
F0H
7FH,7FH,09H,01H,0nH,ppH,rrH
F7H
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
09H
Sub ID#1 (Controller Destination Setting)
01H
Sub ID#2 (Channel Pressure)
0nH
MIDI Channel (00 - 0F)
ppH
Controlled parameter
rrH
Controlled range
pp=0 Pitch Control
rr = 28H - 58H -24 - +24 [semitones]
pp=1 Filter Cutoff Control
rr = 00H - 7FH -9600 - +9450[cents]
pp=2 Amplitude Control
rr = 00H - 7FH 0 - 200%
pp=3 LFO Pitch Depth
rr = 00H - 7FH 0 - 600[cents]
pp=4 LFO Filter Depth
rr = 00H - 7FH 0 - 2400[cents]
pp=5 LFO Amplitude Depth
rr = 00H - 7FH 0 - 100%
F7H
EOX (End Of Exclusive)
❍
Controller
Status
Data byte
Status
F0H
7FH,7FH,09H,03H,0nH,ccH,ppH,rrH
F7H
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
09H
Sub ID#1 (Controller Destination Setting)
03H
Sub ID#2 (Control Change)
0nH
MIDI Channel (00 - 0F)
ccH
Controller number (01 - 1F, 40 - 5F)
ppH
Controlled parameter
rrH
Controlled range
pp=0 Pitch Control
rr = 28H - 58H -24 - +24[semitones]
pp=1 Filter Cutoff Control
rr = 00H - 7FH -9600 - +9450[cents]
pp=2 Amplitude Control
rr = 00H - 7FH 0 - 200%
pp=3 LFO Pitch Depth
rr = 00H - 7FH 0 - 600[cents]
pp=4 LFO Filter Depth
rr = 00H - 7FH 0 - 2400[cents]
pp=5 LFO Amplitude Depth
rr = 00H - 7FH 0 - 100 %
F7H
EOX (End Of Exclusive)