Preli m inary – Runco VX-44D User Manual
Page 106

90
Runco VX-44d/-55d Installation/Operation Manual
P
RELI
M
INARY
Input Position Commands
IHEIGHT
0/20
YES
Sets the value for input height
IHEIGHT?
NA
NA
Returns input height value
IHPOS
-50/50
YES
Sets a value for horizontal input position
IHPOS?
NA
NA
Returns input horizontal position value
IVPOS
-50/50
YES
Sets a value for vertical input position
IVPOS?
NA
NA
Returns input vertical position value
IWIDTH
0/50
YES
Sets the value for input width
IWIDTH?
NA
NA
Returns input horizontal width value
OVERSCAN
0/20
YES
Sets the overscan percentage
OVERSCAN?
NA
NA
Returns overscan percentage
OVERSCANMODE
0/1
YES
Sets the overscan mode (0=zoom;
1=crop)
OVERSCANMODE?
NA
NA
Returns the overscan mode (0=zoom;
1=crop)
Output Shift Commands
OHEIGHT
-50/50
YES
Sets the value for output height
OHEIGHT?
NA
NA
Returns output height value
OHPOS
-50/50
YES
Sets the value for output horizontal posi-
tion
OHPOS?
NA
NA
Returns output horizontal position value
OVPOS
-50/50
YES
Sets the value for output vertical position
OVPOS?
NA
NA
Returns output vertical position value
OWIDTH
-50/50
YES
Sets the value for output width
OWIDTH?
NA
NA
Returns output horizontal width value
Table 6-1. Serial Commands (continued)
Command
Parameter
(min/max)
Value
Stored?
Description