Table 6-1 . serial commands, Preli m inary – Runco VX-44D User Manual
Page 104

88
Runco VX-44d/-55d Installation/Operation Manual
P
RELI
M
INARY
Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the
valid parameter ranges, or “NA” for commands that take no parameters.
When you enter a valid command, the DHD Controller executes it and acknowledges it
with a plus sign on the command line (+ >). When you enter an invalid command – one
that is misspelled or followed by values outside the valid range for that command – the
DHD Controller ignores it and returns a minus sign (- >).
Table 6-1. Serial Commands
Command
Parameter
(min/max)
Value
Stored?
Description
Power On/Off Commands
OFF
NA
NA
Turns projector off
ON
NA
NA
Turns projector on
POWER
0/1
NA
Turns projector on and off
POWER?
NA
NA
Returns power status
Input Selection Commands
COMPONENT
NA
YES
Selects the Component input
COMPOSITE
NA
YES
Selects the Composite video input
HDMI1
NA
YES
Selects the HDMI 1 input
HDMI2
NA
YES
Selects the HDMI 2 input
HD1
NA
YES
Selects the RGB HD 1 input
HD2
NA
YES
Selects the RGB HD 2 input
INPUT?
NA
NA
Returns active input
SCART
NA
YES
Selects the SCART input
SVIDEO1
NA
YES
Selects the S-Video 1 input
SVIDEO2
NA
YES
Selects the S-Video 2 input
Aspect Ratio Commands
16:9
NA
YES
Selects the 16:9 aspect ratio
4:3
NA
YES
Selects the 4:3 aspect ratio
ASPECT?
NA
NA
Returns current aspect ratio
CINEMA
NA
YES
Selects the Cinema aspect ratio
LETTERBOX
NA
YES
Selects the Letterbox aspect ratio
NATIVE
NA
YES
Selects the Native aspect ratio
VIRTUALWIDE
NA
YES
Selects the VirtualWide aspect ratio
VIRTUALCINEMA
NA
YES
Selects the Virtual Cinema aspect ratio