SLEEVE AND MANIFOLD INSTALLATION

METHOD FOR STANDARD WALLS

5. Check rubber seal is in place on terminal.

* For weather board walls, add spare rubber
seal provided to compensate for weatherboard
angle.

6. Installation of Terminal

From outside, insert terminal into sleeve with
the “A” mark at the top. Left hand side fixing tie
is marked “LEFT” (from inside).

7. Attaching Ties

Pull hard on left and right hand side ties, clip
ties over lugs inside sleeve. You should be
able to pull ties 2 or 3 slots past the starting
point. Cut the ties, leaving about 20mm past
the lugs. Bend ties so they are parallel with the
wall.

8. Insert Inner Connection Assembly. Push

assembly into the terminal tube, make sure
“TOP” mark is uppermost. Fix with 3 screws
provided.

9. Manifold can still be turned after attaching.

Terminal seal

(Add "weather board"
seal here)

Label

Fixing Tie

Terminal

"TOP" mark "A"

Cut (leave 20mm free)

Pull hard

Fixing tie

Lug

Sleeve

Terminal

lnner
Connections

Screw

Top Mark

Inlet

20

˚

Outlet

Rubber cap