beautypg.com

Sleeve and manifold installation, Method for standard walls – Rinnai RHFE-308 FTR User Manual

Page 29

background image

– 29 –

SLEEVE AND MANIFOLD INSTALLATION

METHOD FOR STANDARD WALLS

1. Dis-assemble Manifold from Sleeve.

The flue consists of 3 parts, sleeve, inside
connectors and tube, outside terminal; (dis-
assemble by pulling hard on outside terminal
and inner connections, then pull sleeve off outer
terminal).

2. Adjustment of Sleeve Length.

Measure wall thickness through previously
drilled 80mm hole.
End of sleeve should protrude 5-10mm from
outside wall. Adjust sleeve length to wall
thickness plus 5-10mm. (Sleeve is threaded for
adjustment).

3. For A and S flues only

Depending on flue set and wall thickness
extension piece “C” may need to be removed.
Cut plastic, remove extension, then follow
instruction 2.
This applies to “A” and “S” flues only.
There is no extension on other flues, they can
be fully adjusted by turning the threaded
section.

4. Fixing Sleeve.

Fix to the wall, using the 3 screws provided.

NOTE:
The flange is marked “TOP”, sleeve must be
fitted with this mark UP.
Check sleeve protrudes 5-10mm on the
outside.

Connections

Sleeve

Terminal

Extension joint
under plastic

Extension

(‘A’ and ‘S’ flues only)

Adjust length by turning sleeve.

A

B

C

Remove extension at this
point if necessary.

Fixing Screw

2

°

"TOP"

5-10mm

Don't remove green plastic covering from sleeve.