LOCATION

Do not flue into natural draught flues or fireplaces,
this unit can only be used with one of the six types
of Rinnai flue kits.
Do not flue unit into other rooms.
Flue terminal must be outside.

Flue may be positioned directly under opening
windows, with a minimum clearance of 300mm.

FLUE SIZES:

6 Flue lengths are available.
S

flue suits wall

75

-

115 mm

A

flue suits wall

115

-

240 mm

B

flue suits wall

240

-

400 mm

C

flue suits wall

400

-

600 mm

D

flue suits wall

600

-

800 mm

E

flue suits wall

800

-

1000 mm

Co-ax flue also available.

SNOW AREAS

In areas subject to heavy snowfall, keep snow clear
of flue terminal at all times.

GAS CONNECTION

Fit suitable copper flare elbow to appliance inlet.

STANDARD INSTALLATION OF FLUE
MANIFOLD.
Diagram below shows minimum clearances and
distances from obstructions. Also check local
regulations.

Wall

Non
Flammable

Flammable

Opposite
Wall

Floor

300mm

600mm

375mm

600mm

300mm

Obstruction

Snow

Side Clearances

FIT BACK COVERS (SIDES ONLY)