– 26 –

LOCATION

Do not install the heater in an unusually dusty area.

• Use a flue guard if the terminal is easily

accessible to children.

• Check local regulations.
• Guards are available as an optional extra.

• Floor must be level.
• Do not use electrical extension cords to connect

the unit to a power supply.

• Keep the power cord away from the flue.

FLUE MANIFOLD POSITION

Important

The centre of the hole for the flue manifold
must only be drilled in the position indicated on
the diagram below.

Before drilling the flue hole, check for water and
gas pipes as well as electric cables.

For weatherboard walls drill through centre of
the weatherboard from the outside, then drill
from inside through the plaster board.

WALL MOUNTING BRACKETS

• Place top back spacer.
• Mark the position of the top edge of the top

spacer on the wall.

• Move the heater away from the wall.
• Mark the centre lines 30mm down from the top

edge mark, and 40mm in from the left and right
hand sides of the top spacer.

• Attach wall brackets at the marked positon.

Remove right hand back spacer.

217

115

677

265

Drill Hole
80mm
thru wall

Flue Elbow

All measurements are taken from
the extremities of the appliance.