POSITIONING THE FLUE TERMINAL

O

H

N

N

M

Q

M

H

K

B

P

Q

Q

I

F

L

J

G

C

A

I

D,E

Dimension

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

Terminal Position

Directly below an opening, air brick, opening windows, etc.

Above an opening, air brick, opening window, etc.

Horizontally to an opening, air brick, opening window, etc.

Below gutters, soil pipes or drain pipes.

Below eaves.

Below balconies or car port roof.

From a vertical drain pipe or soil pipe.

From an internal or external corner.

Above ground, roof or balcony level.

From a surface facing the terminal.

From a terminal facing a terminal.

From an opening in a car port. (e.g. door, window) into a dwelling.

Vertically from a terminal on the same wall.

Horizontally from a terminal on the same wall.

From the wall on which the terminal is mounted

From a vertical structure on the roof.

Above an intersection with roof.

Distance

300mm

300mm

300mm

75mm

200mm

200mm

150mm

200mm

300mm

600mm

1200mm

1200mm

1500mm

300mm

N/A

N/A

N/A