beautypg.com

Hrough 4-6 – National Instruments AT E Series User Manual

Page 60

background image

Chapter 4

Connecting Signals

© National Instruments Corporation

4-13

AT E Series User Manual

PFI6/WFTRIG

DIO

Vcc +0.5

3.5 at

(Vcc –0.4)

5 at 0.4

1.5

50 k

Ω pu

PFI7/STARTSCAN

DIO

Vcc +0.5

3.5 at

(Vcc –0.4)

5 at 0.4

1.5

50 k

Ω pu

PFI8/GPCTR0_SOURCE

DIO

Vcc +0.5

3.5 at

(Vcc –0.4)

5 at 0.4

1.5

50 k

Ω pu

PFI9/GPCTR0_GATE

DIO

Vcc +0.5

3.5 at

(Vcc –0.4)

5 at 0.4

1.5

50 k

Ω pu

GPCTR0_OUT

DO

3.5 at

(Vcc –0.4)

5 at 0.4

1.5

50 k

Ω pu

FREQ_OUT

DO

3.5 at

(Vcc–0.4)

5 at 0.4

1.5

50 k

Ω pu

AI = Analog Input

DIO = Digital Input/Output

pu = pull up

AO = Analog Output

DO = Digital Output

The tolerance on the 50 k

Ω pull-up and pull-down resistors is very large. Actual value may range between 17 kΩ and 100 kΩ.

Table 4-6. I/O Signal Summary for the AT-MIO-16XE-50

Signal Name

Drive

Impedance

Input/

Output

Protection

(Volts)

On/Off

Source

(mA at V)

Sink

(mA at V)

Rise

Time

(ns)

Bias

ACH<0..15>

AI

20 G

Ω in

parallel with

100 pF

25/15

±3 nA

AISENSE

AI

20 G

Ω in

parallel with

100 pF

25/15

±3 nA

AIGND

AO

DAC0OUT

AO

0.1

Short-circuit

to ground

5 at 10

5 at –10

2

V/µs

DAC1OUT

AO

0.1

Short-circuit

to ground

5 at 10

5 at –10

2

V/µs

AOGND

AO

DGND

DO

Table 4-5. I/O Signal Summary for the AT-MIO-16XE-10 and AT-AI-16XE-10 (Continued)

Signal Name

Drive

Impedance

Input/

Output

Protection

(Volts)

On/Off

Source

(mA at V)

Sink

(mA at V)

Rise

Time

(ns)

Bias