Physical, Maximum working voltage, Environmental – National Instruments AT E Series User Manual
Page 142: Safety
Appendix A
Specifications for AT-MIO-16XE-50
© National Instruments Corporation
A-37
Physical
Dimensions
(not including connectors) ..................... 33.8 by 9.9 cm
(13.3 by 3.9 in)
I/O connector.......................................... 68-pin male SCSI-II type
Maximum Working Voltage
Maximum working voltage refers to the signal voltage plus the
common-mode voltage.
Channel-to-earth..................................... 42 V, Installation Category II
Channel-to-channel ................................ 42 V, Installation Category II
Environmental
Operating temperature............................ 0 to 55 °C
Storage temperature ............................... –20 to 70 °C
Humidity ................................................ 10 to 90% RH, noncondensing
Maximum altitude .................................. 2,000 meters
Pollution degree (indoor use only)......... 2
Safety
The DAQ device meets the requirements of the following standards for
safety and electrical equipment for measurement, control, and laboratory
use:
•
EN 61010-1:1993/A2:1995, IEC 61010-1:1990/A2:1995
•
UL 3101-1:1993, UL 3111-1:1994, UL 3121:1998
•
CAN/CSA c22.2 no. 1010.1:1992/A2:1997