beautypg.com

Slot 0 register descriptions – National Instruments SCXI-1163 User Manual

Page 53

background image

Chapter 4

Register Descriptions

© National Instruments Corporation

4-7

SCXI-1163 User Manual

Slot 0 Register Descriptions

Slot 0 has three registers–the FIFO Register, the Hardscan Register, and the Slot-Select Register.
Only the Slot-Select Register is relevant to this module. The Slot-Select Register is a 16-bit
write-only register that determines with which slot the data acquisition board speaks when
SLOT0SEL* is released high. With the SCXI-1001 chassis, the Slot-Select Register also
determines in which chassis the desired slot is. Write to the Slot-Select Register using the
SLOT0SEL* line. Maintain software copies of the Slot-Select Register.

If you are using multiple chassis, it is important to understand the architecture of the Slot-Select
Register. Although each chassis has its own physical Slot-Select Register, all are written to at
the same time. The jumper settings in Slot 0 of a chassis determine with which chassis number
Slot 0 is identified. From the software perspective, only one Slot-Select Register exists in a
system composed of multiple chassis.