Appendix D Register-Level Programming

National Instruments Corporation

D-17

PC-LPM-16/PnP User Manual

A/D Clear Register

Write to this register to reset the ADC. This operation clears the data FIFO. All error bits
in the Status Register are cleared as well. For the PC-LPM-16 (non PnP only), writing to
this register clears the data FIFO and loads a single conversion into the FIFO. After
writing to the A/D Clear Register, it is necessary to read both the High- and Low-Byte
FIFOs. The data that is read back should be ignored.

Address:

Base address + 01 (hex)

Type:

Write-only

Word Size:

8-bit

Bit Map:

Not applicable, no bits used